Metal Fittings With PVC 2729 6" Dust Collection Duct

  • Advertise with us

« back to Focus on the Workspace forum

Forum topic by charles66 posted 11-10-2014 04:45 PM 1166 views 0 times favorited 5 replies Add to Favorites Watch
View charles66's profile


3 posts in 1460 days

11-10-2014 04:45 PM

Does anyone have any experience with using metal fittings with 6” PVC 2729 sewer and drain pipe for dust collection ductwork? I plan on using mostly PVC fittings but there are some metal fittings that would better suit my setup and they aren’t available in PVC. The questions is how to you mate up and join the metal fittings to PVC. Thanks! Chuck

5 replies so far

View ChrisK's profile


1794 posts in 2498 days

#1 posted 11-10-2014 07:30 PM

The 6” PVC will be 6-5/8 OD the metal fittings will be 6” OD. The step at the joint will a problem with the dust catching the step. I do not know of any adapters for pipe to duct. You might want to stick with one or the other.

-- Chris K

View Fred Hargis's profile

Fred Hargis

3836 posts in 1910 days

#2 posted 11-10-2014 08:24 PM

I’ve done it. It’s not perfect, but it works. In the pic you see the 6” PVC going into a 6×7 transition, I needed 7” going into the cyclone. You also see the fitting is backwards, the air is heading into the male end. I taped the joint inside with foil tape to smooth it over. We get wrapped up a lot on perfection, but do what you have to… will probably work just fine. You also see the transition goes into a 7” adjustable el, and it pretty much locked in place with the same foil tape. The clamp is around the PVC because I put 6 slits in the end to force it over the metal, the clamp holds it together and silicone made sure nothing leaked there. Not pretty, but functional.

-- Our village hasn't lost it's idiot, he was elected to congress.

View buildingmonkey's profile


242 posts in 964 days

#3 posted 11-11-2014 07:54 PM

I saw a thread somewhere, probably on SMC where someone used a heat gun to stretch the plastic a little to make a fit. You could probably make a sheetmetal clamp with a couple bolts to squeeze the pipe down a little, and heat with the gun while you tighten the bolts. I have cut short pieces of pipe, then sawed a little off and used as fillers to reduce the size by a little. Also there are Fernco plumbing adapters that might work. I have metal ducting, and I used a hand held crimper to help me fit pipe together. Just remember to put the joint so the edge of the pipe does not point into the flow of air. A little scrap of wood could cause a plug in your system.

-- Jim from Kansas

View charles66's profile


3 posts in 1460 days

#4 posted 11-16-2014 02:27 AM

Thanks everyone for the helpful responses appreciate it. Still not sure if I will attempt to integrate some metal fittings, might be more trouble than it is worth so might just stick with all PVC.

View shipwright's profile


7080 posts in 2215 days

#5 posted 11-16-2014 03:51 PM

Have a look at this blog. I used stove pipe on my planer and the crimped end is a nice fit in my 6” underfloor PVC. It’s been working well for almost ten years. There are also some tips on making PVC “Y” fittings in another segment of the same blog that may save you some money.

-- Paul M ..............If God wanted us to have fiberglass boats he would have given us fibreglass trees.

Have your say...

You must be signed in to reply.

DISCLAIMER: Any posts on LJ are posted by individuals acting in their own right and do not necessarily reflect the views of LJ. LJ will not be held liable for the actions of any user.

Latest Projects | Latest Blog Entries | Latest Forum Topics