Hi guys,

I have a basement workshop (roughly 12’x25’) that also has the furnace and water heater (both gas) for the first floor of my house in said shop area. Further back story, the basement is connected to the garage which the driveway goes to underneath the house, and there is a window on the back side of my shop facing the back yard.

I’m in the process of figuring out what I’m going to do for dust collection and have just purchased the smaller Rikon air filter and Grizzly hanging dust collector.

My question: I know that it’s dangerous and not advisable to have a dust collection vac in a different room or outside of the shop when there is the water heater in the shop since it creates a negative pressure in the room which allows harmful gas to come into the room and not vent properly. BUT, since I’m having the dust collector and air filter in the same room/shop area I shouldn’t have to worry about that negative pressure being created correct? Lastly, if I do still need to worry about the pressure would simply opening the window create enough new air flowing into the shop to negate the thrown off pressure in the room?

Thanks a ton for any advice and insight!

-- -Chris


6 replies so far

View Mark Shymanski's profile

Mark Shymanski

5314 posts in 3173 days


#1 posted 05-19-2014 02:12 PM

If the collector is venting into the same space it is drawing from there is not net change in pressure and thus won’t affect the room’s air pressure. By opening a window to the same space where the DC is you will equalize the pressure.

-- "Checking for square? What madness is this! The cabinet is square because I will it to be so!" Jeremy Greiner LJ Topic#20953 2011 Feb 2

View cmillsrun's profile

cmillsrun

32 posts in 1018 days


#2 posted 05-19-2014 02:20 PM

Great! That’s what I thought would be the case but just wanted to verify. Thanks again!

-- -Chris

View woodchuckerNJ's profile

woodchuckerNJ

1153 posts in 1095 days


#3 posted 05-19-2014 02:20 PM

Like Mark said +1

-- Jeff NJ

View Shawn Masterson's profile

Shawn Masterson

1297 posts in 1409 days


#4 posted 05-19-2014 02:31 PM

Spot on mark

View kdc68's profile

kdc68

2526 posts in 1737 days


#5 posted 05-19-2014 02:53 PM

Another consideraion is if your shop is conditioned space..opening a window to regulate air pressure might impact your heating and cooling….

-- Measure "at least" twice and cut once

View cmillsrun's profile

cmillsrun

32 posts in 1018 days


#6 posted 05-19-2014 06:47 PM

For my shop, there is not air conditioning so I won’t have to worry about that (which is nice in this instance but sometimes a pain when it’s super hot in the summer or super cold in the winter).

Thanks for the feedback, I think this is going to work just right. Now to just figure out the right placement and dust collection hoses/duct work!