Has anyone purchased, installed and been using the new Clear Vue EF5 cyclone ? I was looking at the Oneida 5hp Dust Gorilla Pro until I saw this come out with comparable cost.

http://www.clearvuecyclones.com/pentz-ef5/102-pentz-ef5-metal-cyclone-with-filters-single-phase.html#/76-intake_size-6_nordfab_qf_intake/78-collection_bin_size-30_gallon_steel_drum


13 replies so far

View Fred Hargis's profile

Fred Hargis

5177 posts in 2696 days


#1 posted 12-04-2018 11:33 AM

I have not, I bought the plastic one a little over a year ago. Had I known this was coming I might have waited and bought it. I suspect you will get better performance out of the CV since it comes with a 16” impeller. I also like that way the cone fastens, not so much for the cleaning attributes but for ease of installation. Keep up posted if you decide to buy one, I’d be interested in your impressions.

-- Our village hasn't lost it's idiot, he was elected to congress.

View GrantA's profile

GrantA

742 posts in 1610 days


#2 posted 12-04-2018 11:55 AM

I think you’ll love it, I’ve been buying a part at a time (motor here, impeller there haha) for a diy pentz cyclone, which will basically be the EF5 when I’m done. Just have to get my sheet metal guy in gear for the cyclone body now!

View Redoak49's profile

Redoak49

3667 posts in 2191 days


#3 posted 12-04-2018 11:57 AM

Looks like a good unit. I wish that CV would provide a performance curve. I am certain that it really sucks.

View jfynyson's profile

jfynyson

30 posts in 1069 days


#4 posted 12-04-2018 01:38 PM

Yes I would like to see a fan curve as well to help me determine for my system design if paying $100 more really worth it to get the optional 8” inlet vs the 6” inlet. I need this to calc the CFM at each tool based on my estimated static pressure loss to each tool. Im sure the 6” will be enough but I’d still like to know roughly how close am I and if the $100 is really worth it….with this comes more cost also from a 8” duct run and reducer from 8’ to 6” downstream.So in reality it could be a $150+ decision….I like data driven decisions.

On the other hand is ~$150 extra when talking about $3k+ really that much more to “know” you have wrangled in all the power this machine can dish out ?

View Blindhog's profile

Blindhog

94 posts in 1251 days


#5 posted 12-04-2018 02:25 PM

I bought a CV1800 around three years ago and have been using it (almost daily) during that period. While I was somewhat disappointed in some of the assembly details/materials, I have not had any issues with performance/reliability. The unit is used in a 3-car garage conversion and runs 3 machines with additional connections for portable planer/drum sander, bandsaw, etc. It gives me all the suction I need and has provided good service.
I would certainly recommend it. The newer model looks like a good buy. Good luck in your decision.

-- Don't let perfection get in the way of plenty good enough

View fly2low's profile

fly2low

55 posts in 300 days


#6 posted 12-05-2018 09:36 AM

I have the CV1800with the 16 inch impeller. It does suck

to get the most out of the system, I changed the ports in all my machines to 5/4 and 6 inch. It brought a tear to my eye to cut into my shiny SawStop

-- Rich Gig Harbor, WA

View Redoak49's profile

Redoak49

3667 posts in 2191 days


#7 posted 12-05-2018 12:06 PM

I know that everyone recommends the 6” ports and cutting into a shiny machine.

With these larger DC, it may not be needed as you can pull a lot of cfm with the 4” port. With my 5 hp DC and 4” port, I am getting 670 cfm and enough to do a very good job. Would a 6” port do more? Of course, but would not make a difference in dust collection.

View GrantA's profile

GrantA

742 posts in 1610 days


#8 posted 12-06-2018 06:09 PM



I know that everyone recommends the 6” ports and cutting into a shiny machine.

With these larger DC, it may not be needed as you can pull a lot of cfm with the 4” port. With my 5 hp DC and 4” port, I am getting 670 cfm and enough to do a very good job. Would a 6” port do more? Of course, but would not make a difference in dust collection.

- Redoak49


Grab a beverage and do some reading, it wouldn’t make much if any difference in chip collection. For fine dust collection you need more cam than a 4” port is capable of.
http://billpentz.com/woodworking/cyclone/dc_basics.cfm#CFMRequirementsTable

View Manitario's profile

Manitario

2687 posts in 3086 days


#9 posted 12-06-2018 07:21 PM

I have a CV1800. I’ve had it for 8 years in 3 different shops. Works well, have very little dust in the filter clean out (typically only vacuum out once a year). The air quality in my shop is better than my house at least in particle count.
Here’s some data from today:
40×25ft shop
Longest run to 2×4” ports on router table (52ft): 536 CFM
Shortest run to 6” port on mitre saw hood (12ft): 1014 CFM

With these larger DC, it may not be needed as you can pull a lot of cfm with the 4” port. With my 5 hp DC and 4” port, I am getting 670 cfm and enough to do a very good job. Would a 6” port do more? Of course, but would not make a difference in dust collection.

- Redoak49

This is incorrect. Yes, it does make a huge difference whether you have a 6” or a 4” port. Eg. I have 2×4” ports on my TS. Two 4” ports ~ 5.66” diameter pipe. With both ports open, CFM is 536. With one 4” port open, CFM is 95. So, it’s incorrect to think that we can all have 4” ports and make up for it with a larger DC.

As for the new EF5; I imagine that it would give better overall CFM at higher static pressures, simply based on the larger impeller from the CV1800. However, at the added cost of having to install 8” mains…

-- Sometimes the creative process requires foul language. -- Charles Neil

View Fred Hargis's profile

Fred Hargis

5177 posts in 2696 days


#10 posted 12-07-2018 11:44 AM

There’s something else going on if you can only pull 95 CFM through a single 4” duct with a CV 1800. that doesn’t make sense.

-- Our village hasn't lost it's idiot, he was elected to congress.

View GrantA's profile

GrantA

742 posts in 1610 days


#11 posted 12-07-2018 12:41 PM

Fred I’m thinking that’s a typo

View Fred Hargis's profile

Fred Hargis

5177 posts in 2696 days


#12 posted 12-07-2018 07:22 PM

You are probably right…...

-- Our village hasn't lost it's idiot, he was elected to congress.

View Manitario's profile

Manitario

2687 posts in 3086 days


#13 posted 12-08-2018 04:18 AM



There s something else going on if you can only pull 95 CFM through a single 4” duct with a CV 1800. that doesn t make sense.

- Fred Hargis

Sorry, should have been 195 CFM. Still pretty poor. Measured with a Dwyer digital manometer and pitot tube and the exact same procedure as the other CFM measurements I posted.

-- Sometimes the creative process requires foul language. -- Charles Neil