I have researched this online but have not found a clear answer. It seems that when people mention running air lines in the attic, debates quickly start up about copper vs black pipe (then someone mentions PVC and everybody else moans and says “here we go again”)

I’d like to run an air line from my garage to another room of the house, through the attic. Less than 50’.

Usage: light duty. Infrequent. Mainly to be able to use the blow gun around the house.

For $29, I can buy a 3/8” Flexzilla 50’ and be done. I would make connector boxes at the ceilings so no hose needs to go through the walls. Attic is typical Missouri attic with cold winters and hot summers.

May I simply run the hose, or do I need to do anything fancier?

-- Keith - Bolivar, Missouri, http://www.SquareOneWoodworks.com


8 replies so far

View johnstoneb's profile

johnstoneb

2640 posts in 2010 days


#1 posted 02-23-2017 03:28 AM

run the hose if you so desire.

-- Bruce, Boise, ID

View GR8HUNTER's profile

GR8HUNTER

2965 posts in 550 days


#2 posted 02-23-2017 04:19 AM

just run hose ..will be fine :<))

-- Tony Reinholds,Pa. REMEMBER TO ALWAYS HAVE FUN

View JCamp's profile

JCamp

475 posts in 388 days


#3 posted 02-23-2017 03:38 PM

Id give it a go. You can always install a shut off in the garage in case it would blow

-- Whatsoever thy hand findeth to do, do it with all thy might

View Keith Kelly's profile

Keith Kelly

262 posts in 1501 days


#4 posted 02-23-2017 06:10 PM

That was easy. Thanks!

-- Keith - Bolivar, Missouri, http://www.SquareOneWoodworks.com

View OnhillWW's profile

OnhillWW

112 posts in 1070 days


#5 posted 02-23-2017 07:30 PM

OK, let me be the contrarian. If this is going to be constantly under pressure, i.e. not only charged when needed, I would not go with a non-metallic supply line. Why? Because, the heat of the attic will eventually degrade the plastic, rubber whatever and if it blows when you are not there the compressor will run an run and run and overheat and possibly cause a fire. The chance is small but is it worth it?? Not in my house. I always run 1/2” galvanised pipe, not that expensive but as my dad always says – “Cheap is expensive”. Good luck.

View hotbyte's profile

hotbyte

989 posts in 2813 days


#6 posted 02-23-2017 07:41 PM

In addition to cut-off valve, perhaps an easy way to bleed pressure off when not in use.

View PPK's profile

PPK

870 posts in 647 days


#7 posted 02-23-2017 09:02 PM

I make a practice of making sure my air compressor is shut off/ unplugged whenever I’ll be gone. That way if an air connection did go, the machine won’t run and be a hazard, or simply waste electricity / put extra wear on it. I agree with the rest. Run a flexzilla hose. They are good stuff.

-- Pete

View Jim Finn's profile

Jim Finn

2577 posts in 2760 days


#8 posted 02-24-2017 01:41 AM

I have my compressor connected to my shop from a separate building and have just a hose for it. Been there four years now and still working fine. I keep the pressure at 90 lbs.

-- No PHD, but I have a GED and my DD 214