LumberJocks

All Replies on Harbor freight 1 HP dust collector

  • Advertise with us
View Horseman2's profile

Harbor freight 1 HP dust collector

by Horseman2
posted 08-14-2017 05:27 PM


4 replies so far

View Horseman2's profile

Horseman2

4 posts in 279 days


#1 posted 08-15-2017 11:01 AM

I found the post by Why Me giving the capacitor micro farads as 400 uf. Went to Grainger Supply and bought a 400 uf start capacitor, installed it and now my dust collector works fine. Thanks Why Me!

View Gilley23's profile

Gilley23

489 posts in 376 days


#2 posted 08-15-2017 12:48 PM

Awesome, thanks for sharing that. Plenty of people (myself included)have that dust collector and someone else will eventually need that info.

View Horseman2's profile

Horseman2

4 posts in 279 days


#3 posted 08-15-2017 03:21 PM

OOPS! Now, I don’t believe the 400 uf start capacitor is the right value for the Harbor Freight 1 hp dust collector. After 15 minutes of operation the motor burnt up on my unit.

View Jim Dawson's profile

Jim Dawson

108 posts in 826 days


#4 posted 08-15-2017 05:07 PM



OOPS! Now, I don t believe the 400 uf start capacitor is the right value for the Harbor Freight 1 hp dust collector. After 15 minutes of operation the motor burnt up on my unit.

- Horseman2


Maybe the start capacitor wasn’t the problem.