LumberJocks

All Replies on Conveyor issue supermax 25x2

  • Advertise with us
View Cmonnier's profile

Conveyor issue supermax 25x2

by Cmonnier
posted 08-10-2017 04:04 AM


9 replies so far

View Loren's profile

Loren

10385 posts in 3645 days


#1 posted 08-10-2017 04:13 AM

Check the linkage between the motor and
the drive roller shaft to make sure it’s
not loose.

View Cmonnier's profile

Cmonnier

5 posts in 287 days


#2 posted 08-10-2017 04:18 AM

I did, that was the first thing they had me check was to make sure the flat spots were lined up with the set screws.

View mahdee's profile

mahdee

3883 posts in 1765 days


#3 posted 08-10-2017 11:56 AM

I have a similar problem with my 19-38 I purchased last Fall. The conveyor belt. It has the mind of its own and has ruined several boards. Now, I do quarter turn passes and even with that I get 3+ inches of snips at each end. Small items like coasters get totally ruined. Very frustrating to purchase a $1700 equipment and get this kind of results. One thing I do when the conveyor belt start moving erratically, is to turn it off and back on again. This has been another disappointing purchase for me.

-- earthartandfoods.com

View ClammyBallz's profile

ClammyBallz

434 posts in 1134 days


#4 posted 08-10-2017 06:46 PM

I had an issue with the circuit board burning out and the variable speed stopped working. They sent a new board and it burned out month later. They sent a new motor and board which turned out to be a leeson motor this time instead of an import. So far it’s been working. However, I do have an issue with the DRO dropping the height setting sometimes when the motor is running.

Have you tried loosening the tension on the belt and seeing of you can stop the motor? Maybe one of the rollers is binding.

View Cmonnier's profile

Cmonnier

5 posts in 287 days


#5 posted 08-10-2017 06:57 PM

What do you mean binding ? If I loosen the tension then the belt starts slipping

View Cmonnier's profile

Cmonnier

5 posts in 287 days


#6 posted 09-04-2017 04:21 PM

So after a month of messing around I saw on the website this sander should have a conveyor motor with 100 in lbs of torque. Looking at my motor and the replacement they sent me, they only had 50. Somehow, the wrong motor was installed on the last shipment of machines. So they overnights me the correct motor, and I got them to throw me a few boxes of sand paper for the inconvenience. Up and running now !

View SweetTea's profile

SweetTea

304 posts in 657 days


#7 posted 09-05-2017 11:35 AM

I purchased a SuperMax 25×2 in June. I have yet to power it on and run any stock through it. I thought that these guys had a stellar rep, that is one of the reasons that I went with the 25×2 and not the PowerMatic PM-2244. The other reason was that I wanted the sander with the most horse power. The 25×2 has 5HP and the PM-2244 only has 1.75HP.

How do you know what conveyor motor your machine has and what is the correct motor for the conveyor? I need to check mine.

View Cmonnier's profile

Cmonnier

5 posts in 287 days


#8 posted 09-05-2017 01:41 PM

The conveyor motor has a tag on it that says how much torque it has, compare to that site. If it’s a Baldor you probably have the wrong motor

View splintergroup's profile

splintergroup

2011 posts in 1220 days


#9 posted 09-06-2017 03:16 PM

I had the “pulsing” problem with the conveyor on my PM 16/32. The belt speed control is basically a light dimmer. Replaced the triac and all is well again. Marginal designs are always a disappointment, but diagnosing factory snafus are nearly impossible. I’m glad that worked out for you!