All Replies on Dust collector, cyclone/blower only, no filters, vent outside, can't find vendor

  • Advertise with us
View tworst's profile

Dust collector, cyclone/blower only, no filters, vent outside, can't find vendor

by tworst
posted 09-12-2010 08:14 PM


17 replies so far

View ND2ELK's profile

ND2ELK

13495 posts in 3828 days


#1 posted 09-12-2010 08:24 PM

Penn State Industries sells blower motors. I do not know if this is what you had in mind or not? They are a good company and it is where I got my dust collection system and duct work. Good luck.

God Bless
tom

-- Mc Bridge Cabinets, Iowa

View Sawkerf's profile

Sawkerf

1730 posts in 3122 days


#2 posted 09-13-2010 12:01 AM

Are you really sure that you want to exhaust outside without any sort of filtering? If you heat and/or cool your shop, you’re gonna be moving a LOT of your shop air outside. You’re also going to generate a large pile of sawdust wherever your system exits the building. Hope your neighbors are understanding. – lol

-- Adversity doesn't build character...................it reveals it.

View tworst's profile

tworst

23 posts in 2892 days


#3 posted 09-13-2010 01:18 AM

I have a detached unheated/cooled 2 car garage and I am basically a fair weather wood worker. I had a jointer, planer and contractor table saw with no dust colection at all. I usually work with the 2 car door and entrance door open and run a fan to keep a little air going. I try to do work out in my driveway when possible, fresh air and sunshine is great, but there is enough chips I still have to clean up the bulk of it. I basically do some work, make a big mess, clean up, repeat. So, I want to start a dust collection system just so I don’t have to constantly clean up. I just got a Jet JJP-12 jointer/planer combo with 4” dust port and will eventually get a cabinet table saw. Given my setup, it makes sense to just exhaust to the outside, since I am not worried about conditioned air loss. This should bring fresh air in from the outside, has to be better than any kind of filtering and recirculation. I should be able to close up the garage doors and just collect the bulk of the dust via cyclone to drum. It is my understanding that the exhaust is only a small amount a fines, so I don’t think there would be much of a saw dust pile outside to worry about.

View tworst's profile

tworst

23 posts in 2892 days


#4 posted 09-13-2010 01:25 AM

P.S. I also don’t have much room in my garage and the filter takes up space that I could use for something else.

View Sawkerf's profile

Sawkerf

1730 posts in 3122 days


#5 posted 09-13-2010 02:06 AM

I think that you’ll be surprised at the amount of fine dust you’ll get – especially if you connect a sander to your DC.

I have the Jet 1100 with a pleated upper filter and usually get 2-3 gallons of fine sanding dust out of it when I empty the bag and clean the filter. And that’s after I give the cleaning paddles 10-12 turns every day.

-- Adversity doesn't build character...................it reveals it.

View ClayandNancy's profile

ClayandNancy

519 posts in 3069 days


#6 posted 09-13-2010 02:13 AM

If you check out Penn Ind. for the blower like ND2ELK suggested, there’s a guy on Ebay selling the cyclone. Just need to hook the blower to the cyclone and get a waste barrel and away you go. Just search dust cyclone on Ebay.

View timberframedave's profile

timberframedave

20 posts in 2864 days


#7 posted 09-15-2010 04:58 PM

I am planning the exact same design for my shop.
There are tons of accessory options for individual parts at: www.oneida-air.com

I would like to build a small shed off the back of 2 car garage – large enough for the cyclone dust collector & air compressor. The intake port of the dust collector will punch through the rear wall of the garage & connect to overhead snap-lock pipe. The exhaust port of the dust collector will exit the shed & run through 10’ of piping – into a stand a trees. This will same some valuable floor space inside the shop & cut down on interior noise.

  • install a manual stop/start switch on rear wall of shop
  • empty sawdust/chip drum at end of each day – while draining down the air compressor tank water (using 1/4” ball valve threaded onto base of compressor)
View PurpLev's profile

PurpLev

8539 posts in 3702 days


#8 posted 09-15-2010 05:01 PM

clearvue cyclones sells the components. you can get everything but the filters from them.

-- ㊍ When in doubt - There is no doubt - Go the safer route.

View tworst's profile

tworst

23 posts in 2892 days


#9 posted 09-15-2010 06:31 PM

Well, now I have a bigger problem. I checked with clear view and thier system uses a 5HP Leeson motor. My 220V feed to my garage is only 20A and total power required is 3HP (table saw) + 5HP = 8HP. No way my 20A has enough juice for this. I would have to run a new dedicated circuit for the DC, which for a number of reasons, would be very difficult. I think I would have to get down in the 2HP range for the DC motor to be able to use my existing 20A circuit while running the table saw. But I thinkg the performance of a 2HP DC would be really poor. So, at this point, its looking like I will just have to work with the garage door open and clean up my mess the old fasioned way.

View brtech's profile

brtech

1034 posts in 2976 days


#10 posted 09-20-2010 03:44 PM

I’d talk to the Clearvue guys. I suspect if you don’t start them at the same time that you will be okay.

View patron's profile

patron

13611 posts in 3395 days


#11 posted 09-20-2010 03:53 PM

here’s what i got
direct outside

just get some 5” heater duct
and a 50’ flex hose
from rockler
and you can move it around if you like
away from the shop

http://www.pennstateind.com/store/DC250SEMB.html

-- david - only thru kindness can this world be whole . If we don't succeed we run the risk of failure. Dan Quayle

View tworst's profile

tworst

23 posts in 2892 days


#12 posted 09-24-2010 12:12 AM

I was hoping that by not using filters, my current draw would go down. I am limited in current capacity, so this was appealilng to me and I was looking at DC systems and slightly derating the current required because of this. Some have said that this will actually increase the current, which is not what I want at all. I think this can only be true because the motor speed is unregulated and it must increase proportionally more than the drop in static pressure caused by removing the filters. I am guessing that all the DC systems out there have unregulated motors, so the RPM and current vary according to operating conditions. Perhaps if I were to add a speed controllers of some sort, I could simply adjust it to keep the current demand within the bounds of my circuit. Does this make sense?

View patron's profile

patron

13611 posts in 3395 days


#13 posted 09-24-2010 02:20 AM

i don’t know much about the teck-speks

i do now that my system sucks

and that’s all i want it to do !

-- david - only thru kindness can this world be whole . If we don't succeed we run the risk of failure. Dan Quayle

View ducky911's profile

ducky911

237 posts in 2843 days


#14 posted 10-06-2010 08:11 PM

Hi,

I too have a seperate from the house two car garage that I have for my work shop.

I have just finished a new dust system to the out side of the shop.

I have a grizzly 2 hp dc to 1 micron it said to be 74 db but at constant noise drives me nuts plus it takes up room and if the bag is not on tight it will leek some fine dust.

I bought a plastic storage shed for outside and put my dc and my compreeor out in it and wired the switches to the inside. I plumbed the dc with sewer pipe pvc sdr 35 6” down to 4” with 7 gates. I just used regular bends and ignored the warnings about pvc pipe and blowing up. I plumbed my compressed air in to three locations with a 100 dollar kit from harbor frieght.

Best thing I ever done quiter and more dust free. I been working one machine at a time to get the on line with the new setup. my dc sucks 1700cfm——I open only one gate at a time and it works with my sander and planer just fine I am thinking of putting in some 6 inch gate valves to isolate a little better.

Bob

View Imacman's profile

Imacman

55 posts in 2879 days


#15 posted 10-08-2010 04:24 AM

I lucked in Last Night…. in my local classfieds last night I found a guy that was advertising some Craftex Air filtration systems for sale for $150 each… I went to see them… and it was actually a commercial wood working shop that had just built a brand new building.. Well I lucked in… he was a nice guy… it was the owner… and he let me have two of them for $200!.. then he uncovers them… turns out he ahd five or six there… and everyone of them are brand spanking new… He looked at me , and said… ” none of these were ever actually used… they were installed but the lazy..so & so’s never bothered to turn them on!”...lol… not a scratch on them… I’m thinking about going back for the rest of them… here is a link to the model Model # CT051, 3amp… anyone have any experience with them?... I’m wondering if I can use one hooked up to a Cyclone type DIY unit, and use it for Point of cutting dust collection??? ideas… My shop is 12 X 21 1800 Cubic feet.

Paul

Imacman

-- It's about the Journey....not the destination.

View Dustyier's profile

Dustyier

4 posts in 2846 days


#16 posted 10-08-2010 04:31 AM

If you don’t mind some retrofiting, you might try HGR industrial surplus in Cleveland Ohio. A lot of their stuff is 3 phase, but I have seen cyclones in the place and other components for sale separately.

View Gator's profile

Gator

383 posts in 3730 days


#17 posted 10-11-2010 07:45 PM

The main issue with venting outside, is air displacment. By removing air from inside your shop, and blowing it outside you create a negative pressure or a vacum inside your shop, that will pulll air in to replace itself from where ever it can, and you just may end up cycling your dust through your collector, blowing it outside, and it will pull it right back into your shop. You could put filtered louvres somewhere so it can pull filtered air into the shop, but depending on how air tight your shop is, you could face an entirely new set of issues. Venting outside is not recomended by any dust collection manufacturers I have talked with without a means of replacing the air, as I also wanted to put my system in a seperate building to eliminate the noise. Venting your heat out is an entirely seperate issue again, especially if you work year in your shop round and live where winter is winter.

Gator

-- Master designer of precision sawdust and one of a kind slivers.